16 AWG einstaklings- og heildarvarið XLPE/PVC 600V tækjabúnaðargerð TC-ER kapall

16 AWG einstaklings- og heildarvarið XLPE/PVC 600V tækjabúnaðargerð TC-ER kapall
Details:
· Strandaður ber koparleiðari
·PVC einangrun
· Fylliefni (eftir þörfum)
· Ál pólýester einstaklingsskjöldur
·20 AWG Tinned Copper Drain Wire
· Ál pólýester heildarskjöldur
·Ripcord (eftir þörfum)
·PVC heildarjakki
·Spennustig: 300V
· Hitastig: Metið til 105 gráður
·Stærðarsvið: 18 eða 16 AWG
·Staðall:UL1277
· Fjöldi leiðara: 1-par til 36-pör, og 1-þríhyrningur til 24-þríhyrninga
· Litur: svartur
Send Inquiry
Download
Lýsing
Tæknilegar breytur
Vottun

 

Class B compressed strand shielded tray cable 600V

VARA REAL SHOT

 

XLPE/PVC Type TC-ER cable with Class B stranded copper
XLPE/PVC Type TC-ER cable with bare copper conductor
ASTM B33 tinned copper drain wire XLPE/PVC TC-ER instrumentation cable

ASTM B8 copper conductor 600V instrumentation cable

16 AWG einstaklings- og heildarvarið XLPE/PVC 600V tækjabúnaðargerð TC-ER snúru fyrir iðnaðarferlisstýringu
Þessi 16 AWG IS/OS merkjaleiðsla vara er áreiðanlegXLPE einangrun XLPE/PVC TC-ER tækjasnúra, framleidd semXLPE/PVC gerð TC-ER snúru með RFH-2 einangrunog metið fyrir 600V vinnuspennu, sem hægt er að bjóða sem heill600V XLPE/PVC TC-ER tilboð í tækjabúnaðarsnúruog þjónar sem hugsjónSkipt um IS/OS XLPE/PVC tækjakapalfyrir gamaldags merkjalagnir í iðnaði. Þessi TC-ER bakka snúru er hönnuð með einstaklings- og heildar tvöfaldri vörn, XLPE kjarnaeinangrun ásamt PVC ytri jakka, og skilar sterkum gegn-truflunarafköstum, styður óvarinn hlaup, uppsetningu á bakka og rásum og passar fyrir nákvæman tækjabúnað, brunaviðvörunar- og stjórnrásarlagnir frá verksmiðjunni.
VÖRULEIKNINGAR

 

600V XLPE/PVC TC-ER instrumentation cable China manufacturer

Vörulýsing

 

XLPE/PVC, 600V tækjabúnaður, Tegund TC-ER og Direct Burial Cables samanstanda af fullglöddum berum kopar Class B strandleiðurum (í pörum eða þríhyrningum), þaktir kross-tengdu pólýetýlen (XLPE) einangrun, í heildina varið eða hver fyrir sig og í heildina varið og svart PVC. Þessar snúrur eru notaðar í stjórnkerfi, hljóðkerfi, kallkerfi, viðvörunarrásir og orkustjórnun.

Umsóknir

 
  • Í lausu lofti, rásum, kapalbakkum, rásum, hlaupbrautum og beinni greftrun

  • Samþykkt fyrir hættulegar staðsetningar í flokki I, Div. 2 samkvæmt NEC

  • Leyfilegt fyrir óvarið hlaup (ER) notað í samræmi við NEC fyrir 3 eða fleiri leiðara; tveir leiðarar án jarðvíra eru eingöngu af gerð TC

Eiginleikar

 
  • Metið fyrir 90 gráðu blautt eða þurrt
  • Ripcord (eftir þörfum)
  • Frábær sólarljósþol
  • Uppfyllir kalt beygjupróf við -25 gráður
LEIÐBEININGAR

Hljómsveitarstjóri

Fáanlegt í 1-par til 36-pörum og 1-þríhyrningi til 24-þríhyrninga

Hljómsveitarstjóri

Fullglæður ber kopar flokkur B

Málarstærðir

Fáanlegt í 18 eða 16 AWG

Einangrun

Kross-tengt pólýetýlen (XLPE)
Litakóðun Samkvæmt ICEA S-58-679 Aðferð 9, Tafla E-1 (svart-hvítt-rautt), auk einn leiðara á pari/þríhöggi prentað til auðkenningar; fleiri litakóðunarvalkostir í boði
Skjaldarvalkostir

Á heildina litið (OS): Heildar ál pólýester þynnuhlíf í snertingu við 20 AWG strandaðan tinn kopar frárennslisvír

Einstaklingur og heild (IS/OS): Samsetning bæði einstaklings og heildar með álpólýesterþynnuhlíf í snertingu við 20 AWG strandaðan niðurfallsvír úr kopar

Jakki Pólývínýlklóríð (PVC)

Jakkamerking

00000 FT GREATER WIRE CABLE XXAWG XX/PR (eða TR) XLPE/PVC OS (eða IS eða IS/OS) 600V 90C WET EÐA DRY TYPE TC-ER (UL) SUN RES DIR BUR MADE IN USA MMDDYYYY

Umbúðir

Óafturkræfar tréhjólar í ýmsum lengdum og stærðum

Frammistöðureglur

ASTM B3, ASTM B8, ASTM B33

UL® 44

UL 1277

UL 1685 (logaprófun)

ANSI/NEMA WC 57/ICEA S-73-532

Önnur samræmi

EPA 40 CFR, hluti 261

OSHA

RoHS-samhæft/RoHS 2-samhæft

REACH-samhæft

Almennt varið

Fjöldi para Þríhyrningatalning Hljómsveitarstærð AWG Einangrunarþykkt
í (mm)
Þykkt jakka
í (mm)
U.þ.b. Heildarþvermál
í (mm)
U.þ.b. Nettóþyngd
lbs/kft (kg/km)
1 - 18 0.030(0.76) 0.045(1.14) 0.32(8.2) 50(68)
- 1 18 0.030(0.76) 0.045(1.14) 0.34(8.6) 60(83)
2 - 18 0.030(0.76) 0.045(1.14) 0.46(11.7) 80(113)
4 - 18 0.030(0.76) 0.060(1.52) 0.57(14.5) 135(198)
8 - 18 0.030(0.76) 0.060(1.52) 0.73(18.5) 220(326)
12 - 18 0.030(0.76) 0.080(2.03) 0.92(23.5) 345(506)
16 - 18 0.030(0.76) 0.080(2.03) 1.02(26.0) 425(629)
20 - 18 0.030(0.76) 0.080(2.03) 1.13(28.7) 510(753)
24 - 18 0.030(0.76) 0.080(2.03) 1.26(31.9) 595(882)
36 - 18 0.030(0.76) 0.080(2.03) 1.44(36.5) 820(1,219)
1 - 16 0.030(0.76) 0.045(1.14) 0.35 (8.8) 60(82)
- 1 16 0.030(0.76) 0.045(1.14) 0.37 (9.3) 70(102)
2 - 16 0.030(0.76) 0.045(1.14) 0.50(12.7) 95(140)
4 - 16 0.030(0.76) 0.060(1.52) 0.62(15.7) 170(249)
8 - 16 0.030(0.76) 0.060(1.52) 0.80(20.2) 285(421)
12 - 16 0.030(0.76) 0.080(2.03) 1.01(25.6) 440(651)
16 - 16 0.030(0.76) 0.080(2.03) 1.12(28.4) 550(817)
20 - 16 0.030(0.76) 0.080(2.03) 1.24(31.4) 665(986)
24 - 16 0.030(0.76) 0.080(2.03) 1.37(34.9) 780(1,159)
36 - 16 0.030(0.76) 0.080(2.03) 1.57(40.0) 1,095(1,625)
Sérstaklega og í heildina varið
Fjöldi para Hljómsveitarstærð AWG Einangrunarþykkt
í (mm)
Þykkt jakka
í (mm)
U.þ.b. Heildarþvermál
í (mm)
U.þ.b. Nettóþyngd
lbs/kft (kg/km)
2 18 0.030(0.76) 0.045(1.14) 0.50(12.8) 70(102)
4 18 0.030(0.76) 0.060(1.52) 0.62(15.7) 95(135)
8 18 0.030(0.76) 0.060(1.52) 0.80(20.3) 115(168)
12 18 0.030(0.76) 0.080(2.03) 1.01(25.7) 150(218)
16 18 0.030(0.76) 0.080(2.03) 1.12(28.5) 200(291)
20 18 0.030(0.76) 0.080(2.03) 1.24(31.5) 275(404)
24 18 0.030(0.76) 0.080(2.03) 1.38(35.1) 295(433)
36 18 0.030(0.76) 0.080(2.03) 1.58(40.2) 390(575)
2 16 0.030(0.76) 0.060(1.52) 0.58(14.7) 120(175)
4 16 0.030(0.76) 0.060(1.52) 0.67(17.0) 185(271)
8 16 0.030(0.76) 0.080(2.03) 0.91(23.1) 350(517)
12 16 0.030(0.76) 0.080(2.03) 1.10(27.9) 485(719)
16 16 0.030(0.76) 0.080(2.03) 1.22(31.0) 610(906)
20 16 0.030(0.76) 0.080(2.03) 1.36(34.4) 740(1,095)
24 16 0.030(0.76) 0.080(2.03) 1.51(38.3) 870(1,289)
36 16 0.030(0.76) 0.110(2.79) 1.79(45.5) 1,320(1,963)
VOTTANIR

 

XLPE/PVC overall shielded pairs triads equivalent

PAKNINGAR

 

600V XLPE/PVC instrumentation cable for energy management

Rúlla

XLPE/PVC TC-ER instrumentation cable for automation wiring

Plast spóla

600V XLPE/PVC instrumentation cable for industrial control

Lítil trévinda

UMSÓKN

 

600V XLPE/PVC Type TC-ER replacement cable
Verksmiðju sjálfvirkni
600V XLPE/PVC TC-ER instrumentation cable cut to length
Vinnubúnaður
600V XLPE/PVC TC-ER instrumentation cable distributor
Vatnsmeðferðarstýringarkerfi
MÁLI

 

XLPE/PVC 600V Instrumentation Type TC-ER cable TC-ER cable supplier

BASF Ludwigshafen Verbund Site

XLPE/PVC 600V Instrumentation Type TC-ER cable cable manufacturer

MWRA Deer Island skólphreinsistöð

XLPE/PVC 600V Instrumentation Type TC-ER cable quote

Siemens Electronic Works Amberg verksmiðjan

AFHVERJU VELJA OKKUR

 

30Margra ára reynsla
í-einni þjónustu

Dongguan Greater Wire & Cable Co., Ltd. er faglegur-kaplaframleiðandi í Kína, sem útvegar vottaðar rafstrengjalausnir fyrir byggingar-, iðnaðar-, námu-, orku- og innviðaverkefni um allan heim.

Með 30.000 m² verksmiðju, 30 framleiðslulínum, reyndum verkfræðingum og ströngu gæðaeftirlitsteymi, bjóðum við upp á áreiðanlegar, rekjanlegar og samhæfðar kapalvörur fyrir alþjóðleg verkfræðiforrit. Vörur okkar eru studdar af vottunum þar á meðal SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS og ISO.

Við leggjum áherslu á öryggi, gæði, gagnsæi og langtíma-samstarf. Frá skoðun á hráefni til prófunar á fullunnum vöru, er hverri lotu stjórnað vandlega til að tryggja stöðugan árangur og áreiðanlega verkefnanotkun.

Meiri kapal - vottuð gæði. Áreiðanlegt framboð. Verkfræðiverðmæti.

cross-linked polyethylene insulation XLPE/PVC TC-ER instrumentation cable
 
15K
Lokið verkefni
150+
faglegt starfsfólk
15K
ánægðir viðskiptavinir
92+
verðlaun og skírteini
PLÖTTUbúnaður

 

XLPE/PVC Type TC-ER cable with Class B compressed strand
 
Class B compressed strand 600V instrumentation cable
 
Class B stranded copper 600V instrumentation cable
 
fully annealed bare copper shielded tray cable 600V
 
ASTM B8 copper conductor shielded tray cable 600V
 
XLPE/PVC Type TC-ER cable with ASTM B33 tinned copper drain wire
 
GLOBAL VOTTANIR

 

Class B stranded copper shielded tray cable 600V

VIÐSKIPTAMYNDIR
 

bare copper conductor shielded tray cable 600V

ALÞJÓÐLEG SAMGÖNGUR

 

01

Sjófrakt

Við bjóðum upp á áreiðanlegar sjófraktlausnir fyrir stórar-pantanir. Vörurnar þínar eru tryggilega pakkaðar og sendar í gámum, sem tryggir -hagkvæma afhendingu til hafna um allan heim.

02

Flugfrakt

Fyrir hraðari afhendingu tryggir flugfraktþjónusta okkar að vörur þínar komist fljótt til alþjóðlegra áfangastaða, með varkárri meðhöndlun og fullri rakningu á leiðinni.

03

International Express

Þarftu brýnar sendingar? Alþjóðleg hraðþjónusta okkar skilar litlum og meðalstórum pöntunum á skilvirkan hátt og veitir -að-dyraþjónustu með rauntíma-rakningu fyrir hugarró.

XLPE/PVC TC-ER instrumentation cable for ducts
SAMSTARFSMAÐI

 

Við leitum að samstarfsaðila til að auka viðskipti okkar.

XLPE/PVC TC-ER instrumentation cable for aerial installation
XLPE/PVC 600V Type TC-ER wet dry locations
XLPE/PVC 600V Type TC-ER direct burial
shielded XLPE/PVC instrumentation cable for cable tray
XLPE/PVC TC-ER instrumentation cable for free air
600V XLPE/PVC tray cable for beverage production
600V XLPE/PVC TC-ER instrumentation cable for beverage production
XLPE/PVC Type TC-ER cable for beverage production
XLPE/PVC Type TC-ER cable for manufacturing plant
XLPE/PVC Type TC-ER cable for food processing plant
Hvernig á að vinna með okkur?

Deildu einfaldlega kröfum þínum, fáðu faglega lausnina okkar, staðfestu sýnishorn og njóttu hraðrar, áreiðanlegrar framleiðslu og heimsendingar - að vinna með okkur er svo auðvelt.

Heimilisfangið okkar

Bygging 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Kína

Símanúmer

+86 136 6257 9592

+86 135 1078 4550

E-póstur

manager01@greaterwire.com

600V XLPE/PVC tray cable for pharmaceutical plant
Algengar spurningar

 

Af hverju er þessi kapall með bæði einstaklings- og heildarvörn?
Einstök hlífðarvörn verndar hvert par fyrir víxl-spjalli milli para innan sömu snúru. Heildarhlífin veitir viðbótarlag af vörn gegn ytri EMI frá nærliggjandi rafmagnssnúrum og búnaði. Saman veita þeir hámarks merkjavörn.
Hver er munurinn á PLTC og ITC einkunnum?
PLTC (Power-Limited Tray Cable) er fyrir afl-takmarkaðar stjórnrásir. ITC (Instrumentation Tray Cable) er fyrir tækjabúnað og stjórnunarbúnað. Þessi kapall ber báðar einkunnir og býður upp á sveigjanleika fyrir ýmsar stjórnunar- og tækjabúnað.
Hvers konar merki getur þessi kapall borið?
Þessi kapall hentar fyrir hliðræn merki (4-20mA, hitaeining, RTD), stafræn fjarskipti og lágspennustjórnunarmerki í tækjabúnaði og sjálfvirknikerfum.
Er hægt að setja þessa kapal í kapalbakka án leiðslu?
Já, PLTC/ITC einkunnin leyfir uppsetningu kapalbakka. Fyrir óvarinn keyrslu skaltu ganga úr skugga um að uppsetningin uppfylli kóðakröfur fyrir líkamlega vernd.

 

Hot Tags: 16 AWG XLPE/PVC 600V tækjabúnaðargerð TC-ER kapall, 16 AWG, XLPE/PVC 600V búnaður, 16 AWG, XLPE/PVC 600V tækjabúnaður, birgjar, verksmiðja.

Send Inquiry